Room freezing system

The freezing cold rooms were designed to meet the needs of industrial and research laboratories and keep interior temperature.
The freezing cold rooms are perfectly suited for storage of big amounts of all kinds of samples. The freezing cold rooms can be manufactured in different sizes according to our standards or customer’s needs.
The system guarantees stability and tightness of the freezing cold rooms and makes possible later extension of the cold room or dismounting for moving. We offer you the wide range of cold rooms. The cooling machines can be mounted on the top of the cold room, alongside on the wall or remote. Freezing cold rooms can be manufactured as a normal or explosion-proof model.  The doors of the freezing cold rooms are equipped with heavy chromed hinges and chromed lockable push-in safety lock.
The floor of the cold room is made of non-slip and waterproof sandwich panels and high wear resistance.

METHOD OF IMPLEMENTATION FREEZING ROOMS

1. Putting thermal insulation sheets in the hole of the type of Polystyrene Pressure 35kg 2m thickness of 510-cm.
2. Place a nylon layer of 200500- microns.
3. Installation of 6m-10mm reinforcement network.
4. Construction of a concrete layer of 515-cm, 500 calibers.
5. A layer of epoxy or bitumen.
6. Rules of installation of insulating panels -Installation of thickness plates 1020-cm Pressure 4042-kg 2m of perthane with a sheet of greased and thermally treated inside of the outside thickness 0.60.5-mm.
7. Installation of external cooling unit.
8. Installation of the main control panel.
9. Installation of internal cooling units.
10. Installation of heat sensors.
11. Installation of doors with the same specifications.
12. Installation of the thermometer.
13. Behind the doors Plastic curtains fitted with internal safety locks. 14. Lighting Fixtures.
15. Shelves are made of light steel, galvanized, or chrome.
16. Bumper 2 inches greased and thermally treated or chrome. 
 

Specifications and features:

– The sheet metal (9002 AH) white painted surfaces covered with a protective polyurethane layer and can be removed at a later time 0.5 mm.
– Polyurethane density: 42-38 kg / m3.
– Polyurethane thickness: 80 mm. Thermal conductivity (k): 0233 kcal / hour M2 C.
– Polyurethane thickness: 100 mm. Thermal conduction (k): 0189 kcal / hour M2 C.
– Polyurethane thickness: 120 mm. Thermal conductivity (k): 0159 kcal / hour M2 C.
 – Polyurethane thickness: 150 mm. Thermal conduction (k): 0129 kcal / hm2C.
– Thickness of polyurethane: 200 mm. Thermal conductivity (k): 0097 kcal / hour M2 C.

Installation:

– Cold room panels are installed in the form of male and female; And it is rotated Corner. Ceiling / side wall kits with special accessories.

Doors, hardware features and accessories:

 – All doors are heat insulated.
– The doors have a security mechanism that can be opened from the inside.
– Door frame thickness is the same as panel thickness.
– All doors are of high quality.

Strength and pressure:

Pressure fans prevent freezing and reducing dense in cold storage. Thanks to the two-way mechanical valve, air balance and shrinkage are balanced (note -40 ° C).

Radiator features:

– The materials used are ISO 9001: 2000, TSE, CE.
– Refrigerators undergo mechanical and electronic tests.
– A total of 344 separate standard devices for refrigeration applications between + 16 ° S / -50 ° C.
– Condenser surfaces are calculated according to the hardware parameters according to the surrounding conditions + 33 ° C and + 42 ° C. There is also an option for field-type coolers to + 50 ° C.
– The devices are fully automatic and controlled.
– Digital setting with remote control panel can be set to desired temperature. Microproses are controlled with 35 different parameters.
– There is a keyboard lock on the control panel so only responsible personnel can use it for the safety of the device.
The device consists of high quality international brands in the spare parts category.
– The outdoor unit is specially made to be weather-proof; there are control caps that can be opened easily during installation and maintenance.
– The electrical panels can be opened outside and can be opened easily during breakdowns.
– There are different types (standard, cab type, ceiling type) evaporator (room cooler) depending on cold storage specifications, loading type or product specifications.
– Preventing the non-systemic voltage control system from being affected by the transformer in the system.
– All devices are protected against voltage fluctuations (10%) and against phase losses (triphas devices via voltage and phase protection relays).
– Cooling devices are guaranteed for 1 year.
– All coolers are designed for energy saving and high energy saving thanks to the advanced evaporator fan system.
– The size of the outdoor unit is in European Safety Standards (CE) and the outdoor unit (condenser unit) operates at a very low sound level in quiet condensed quality refrigerators.
– Cooling devices operate with automatic fan pressure control system according to summer and winter temperatures (industrial devices).
 

Industrial Coolers - Cold Storage:

– Industrial refrigerators are standard equipment that produces up to 145 kW.
– Standard EN and EN 2 series are produced as evaporator, thus homogeneous air circulation is provided.
– Despite mentioning the large capabilities, the noise level is acceptable under European standards (CE) due to the international quality fans used.
– The outdoor unit has been specially manufactured to be resistant to weather conditions, and central capacitors are used from two lines for large capacitors.
– Capacitor surfaces are calculated according to the device standards, according to the surrounding conditions + 33 ° C and + 45 ° C. There is also an option for field coolers to + 50 ° C.
×